Counter status register
DOWN | When ‘0’, counter is counting up. When ‘1’, counter is counting down. In QUAD mode, this field indicates the direction of the latest counter change: ‘0’ when last incremented and ‘1’ when last decremented. |
GENERIC | Generic 8-bit counter field. In PWM_DT mode, this counter is used for dead time insertion. In all other modes, this counter is used for pre-scaling the selected counter clock. PWM_DT mode can NOT use prescaled clock functionality. |
RUNNING | When ‘0’, the counter is NOT running. When ‘1’, the counter is running. |